• SAFETY
• ASSEMBLY
• OPERATION
• TROUBLESHOOTING
• ELECTRICAL DATA
• PARTS
• WARRANTY
1-800-333-1322
ULTRA SOURCE
Portable Generator
COMMERCIAL • INDUSTRIAL • RESIDENTIAL
MODEL: 004583-0
17,500 Watt Portable Generator
and 60 amp manual transfer switch
with built-in load center
AUTHORIZED DEALER SUPPORT:
Vista de página 0
1 2 3 4 5 6 ... 47 48

Resumo do Conteúdo

Página 1 - ULTRA SOURCE

Owner’sManual• SAFETY• ASSEMBLY• OPERATION• TROUBLESHOOTING• ELECTRICAL DATA• PARTS • WARRANTY1-800-333-1322ULTRA SOURCE Portable GeneratorCOMMERCIAL

Página 2

Figure 9 - 120 VAC, 30 Amp ReceptacleUse this receptacle to operate 120 Volt AC, 60 Hz, single phaseloads requiring up to 3600 watts (3.6 kW) of power

Página 3 - READ THIS MANUAL THOROUGHLY

2.3 HOW TO USE THE GENERATORIf you have any problems operating your generator, please call thegenerator helpline at 1-800-333-1322.2.3.1 GROUNDING THE

Página 4 - WARNING:

2.5 WATTAGE REFERENCE GUIDEDevice . . . . . . . . . . . . . . . . . . . . . . .Running Watts*Air Conditioner (12,000 Btu) . . . . . . . . . . . . .

Página 5 -  EXPLOSION HAZARDS 

2.6.2 ADDING GASOLINE WARNING: Never fill fuel tank indoors. Never fill fuel tankwhen engine is running or hot. DO NOT light a cigarette orsmoke wh

Página 6 - 1.2.2 ASSEMBLING THE HANDLE

• Move engine CHOKE knob to “Full Choke” position.Figure 17 - Full Choke Position• To start engine, press and hold the Start/Run/Stop switch inthe “S

Página 7 - Figure 2 - Handle Assembly

2.12 CHARGING A BATTERYDANGER! Storage batteries give off explosive hydrogen gaswhile recharging. An explosive mixture will remain aroundthe battery

Página 8 - Figure 4 - Control Panel

3.2.1 GENERATOR SPECIFICATIONSMODEL GPS 17,500Model # 004583-0Rated Max. Power 17.5 kWSurge Power 26.2 kWRated AC Voltage 120/240Rated Max AC LoadCurr

Página 9 - 2.2 CORD SETS AND CONNECTION

153.3 GENERAL RECOMMENDATIONSThe warranty of the generator does not cover items that havebeen subjected to operator abuse or negligence. To receive fu

Página 10

3.3.6 REPLACING THE SPARK PLUGUse Champion RC14YC spark plug or equivalent. The correct airgap is 1.01 mm (0.040 in.). Replace the plug once each year

Página 11 - Generator Ground Lug

Figure 21 - Spark Arrestor3.6 ADJUSTING VALVE CLEARANCEAfter the first 50 hours of operation, you should adjust the valveclearance in the engine.Impor

Página 12 - 2.6.1 ADDING ENGINE OIL

Table of ContentsResidential Portable Generator SystemSafety Rules ...1-3Section 1 – General Information ...

Página 13 - Figure 14 - Fuel Tank

3.7 GENERALThe generator should be started at least once every seven daysand be allowed to run at least 30 minutes. If this cannot be doneand you must

Página 14 - 2.11.3 RESTARTING

194.1 TROUBLESHOOTINGEngine is running, but no AC 1. Circuit breaker is open. 1. Reset circuit breaker.output is available. 2. Poor connection o

Página 15 - 2.12 CHARGING A BATTERY

2.3.20Section 5—Installation for Manual Transfer SwitchKIT INCLUDES:1. Power Inlet Box Pre-wired with the 50 amp male receptacle, this box is locatedo

Página 16 - 3.2.2 ENGINE SPECIFICATIONS

21Section 5—Installation for Manual Transfer Switch1. PLAN THE LOCATION OF YOUR GENERATOR(Fig. A) shows the GUARDIAN Ultra Source 17,5000watt portabl

Página 17 - 3.3.4 CHECKING OIL LEVEL

7a. Lift cover of the power inlet box and remove theinternal cover plate screws and internal cover plate.Remove the knock out in the lower center of

Página 18 - 3.4 SERVICE AIR CLEANER

9a. The 2 foot conduit that is pre-wired into the manualtransfer switch is not fastened to the side of theenclosure when shipped. To secure the condui

Página 19 - Figure 21 - Spark Arrestor

USING THE ULTRA SOURCE PORTABLEThe GUARDIAN® ULTRA SOURCE with manual transfer switchgives you the ability to provide power safely and convenientlyto

Página 20 - 3.9 OTHER STORAGE TIPS:

TRANSFER TO GENERATOR POWER SOURCEWHEN UTILITY POWER FAILS1. Move generator to within approximately 10 feet of thepower inlet box. Connect ground stra

Página 21 - 4.1 TROUBLESHOOTING

26Section 6—Operation of Generator with Manual Transfer SwitchINTERCONNECTION DRAWINGULTRASOURCE GENERATOR CONNECTED TO THE EXTERNAL CONNECTION BOX, M

Página 22 - ITEMS YOU MUST PURCHASE:

27Section 7 - NotesResidential Portable Generator System

Página 23 - Silicone

INTRODUCTIONThank you for purchasing this model of the GUARDIAN®productline by Generac Power Systems, Inc. This model is a compact,high performance,

Página 24 - ---  WARNING 

28Section 8 — Electrical DataCommercial-Industrial-Residential Portable Generator SystemWiring Diagram, UltraSource Portable Generator – Drawing No. 0

Página 25 - Your GUARDIAN Ultra Source

29ACTUATORGOVERNOR40CLOSEST TO BEARINGCLOSEST TO BEARINGSTATORSTATOR308587a8687SCBLACK12VBATTERYSMREDSP2SP1IM2FSSLOPDDIM1STOPRUN(START)0ICPIN #1211108

Página 26 - Receptacle

Section 8 — Electrical DataCommercial-Industrial-Residential Portable Generator SystemSchematic, UltraSource Portable Generator – Drawing No. 0G073386

Página 27 - WHEN UTILITY POWER FAILS

Section 8 — Electrical DataCommercial-Industrial-Residential Portable Generator SystemWiring Diagram, Manual Transfer Switch – Drawing No. 0G1065CIRCU

Página 28 - INTERCONNECTION DRAWING

32Section 9 — Exploded Views and Parts ListsCommercial-Industrial-Residential Portable Generator SystemManual Transfer Switch with Load Center – Drawi

Página 29 - Section 7 - Notes

33ITEM PART NO. QTY. DESCRIPTION1 0G0749 1 BOX LOAD CENTER W/HARDWARE2 0G0748 1 CIRCUIT BREAKER INTERLOCK3 0E7888 1 CIRCUIT BREAKER 20A 2P4 0E7888B 5

Página 30 - Section 8 — Electrical Data

34Section 9 — Exploded Views and Parts ListsCommercial-Industrial-Residential Portable Generator SystemGT-990 & GT-760 Engine (Page 1) – Drawing N

Página 31

35ITEM PART NO. QTY. DESCRIPTION1 0C5729 1 ASSEMBLY, CRANKCASE HOUSING WITH SLEEVE2 0E9843 1 SEAL, 38 I.D. CRANKSHAFT 3 090388 3 SCREW, TAPTITE M6-1.0

Página 32

36Section 9 — Exploded Views and Parts ListsCommercial-Industrial-Residential Portable Generator SystemGT-990 & GT-760 Engine (Page 2) – Drawing N

Página 33

ITEM PART # QTY. DESCRIPTION66 0D6592 1 WINGNUT, AIRBOX67 0D4511 1 PRECLEANER, AIR68 0D9723 1 ELEMENT, AIR CLEANER69 0E5302 1 STUD M6-1.0 X 7370 0D418

Página 34

2• Never start or stop the unit with electrical loads connected toreceptacles AND with connected devices turned ON. Start theengine and let it stabil

Página 35

38Section 9 — Exploded Views and Parts ListsCommercial-Industrial-Residential Portable Generator SystemGenerator – Drawing No. 0D4488-F103311388392412

Página 36

39ITEM PART NO. QTY. DESCRIPTION1 0C6934 1 ADAPTOR, ENGINE2 0D2123 1 STATOR 12.5KW0D2134 STATOR 15KW0D2136 STATOR 18KW3 0D21320SRV 1 ASSEMBLY, ROTOR W

Página 37

40Section 9 — Exploded Views and Parts ListsCommercial-Industrial-Residential Portable Generator SystemControl Panel – Drawing No. 0G0727-B

Página 38 - DETAIL "A"

ITEM PART NO. QTY. DESCRIPTION1 087968 1 SWITCH, ROCKER -/02 090418 1 OUTLET, 12VDC SNAP3 0D6640 1 COVER, GOVERNOR CONTROL4 090987 6 SCREW PPHM M3-0.5

Página 39

Section 9 — Exploded Views and Parts ListsCommercial-Industrial-Residential Portable Generator SystemFrame, Handle & Wheel Kit – Drawing No. 0E069

Página 40

43ITEM PART NO. QTY. DESCRIPTION1 057058 4 SCREW HHC M6-1.0 X 552 0D5315 4 RUBBER TANK MOUNT3 0D4570 1 CAP, FUEL WITH GAUGE & VENT4 0D22850SRV

Página 41

44CALIFORNIA EMISSION CONTROL WARRANTY STATEMENTYOUR WARRANTY RIGHTS AND OBLIGATIONSThe California Air Resources Board (CARB) and Generac Power System

Página 42

45EMISSION CONTROL SYSTEM WARRANTYEmission Control System Warranty (ECS warranty) for 2001 and later model year LSI engines:(a) Applicability: This wa

Página 43

GENERAC POWER SYSTEMS "TWO YEAR" LIMITED WARRANTY FOR GUARDIAN®ULTRA SOURCE 17,500 WATT GENERATOR WITH MANUAL TRANSFER SWITCH For a period o

Página 44 - Detail of Battery Tray

 ELECTRICAL HAZARDS• All generators covered by this manual produce dangerous electrical voltages and can cause fatal electrical shock. Utility power

Página 45

1.1 UNPACKING• Set the palleted carton on a rigid flat surface.• Remove staples along bottom of carton that fasten carton topallet. Open carton from

Página 46 - GENERAC POWER SYSTEMS, INC

51.2.3 BATTERY CONNECTION• The battery shipped with the generator has been provided fullycharged. Caution must be taken when connecting the battery

Página 47 - Owner's Manual

6Section 2 – OperationResidential Portable Generator SystemOPERATION2.1 KNOW THE GENERATORRead the Owner’s Manualand Safety Rulesbefore operatingthis

Página 48 - POWER SYSTEMS, INC

14) Start/Run/Stop Switch – Controls the operation of thegenerator.15) Oil Fill – Use this point to add oil to engine.16) Fuse - 10 Amp (Located at re